Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Journal of Medical Postgraduates ; (12): 52-54, 2015.
Article in Chinese | WPRIM | ID: wpr-473592

ABSTRACT

Objective To evaluate the treatment of acute cholecystitis patients through laparoscopic cholecystectomy (LC). Methods 387 cases of acute cholecystitis patients who underwent LC were studied retrospectively . Results Of the 387 cases, there were 359 cases of calculus incarcerated cholecystitis , 152 cases of cholecystitis with acute inflammatory symptoms for 72 h or more, 10 cases were converted to Laparotomy (2.6%).The operations lasted for 30~200 min(63.09 ±26.62 min on average),with blood loss about 10~500 mL(51.41 ±32.41 mL on average),and drainage was adopted in 183 cases.No complications developed fol-lowing the surgeries in 3 to 24 months, indicating a 100% cure rate. Conclusion If with good command of rules and techniques during LC operations , It is both safe and feasible to treat acute cholecystitis patients through LC operations .

2.
The Journal of Practical Medicine ; (24): 966-968, 2015.
Article in Chinese | WPRIM | ID: wpr-464699

ABSTRACT

Objective To explore the diagnostic value of contrast-enhanced ultrasonic intravenous imaging and cholangiography in the diagnosis of malignant jaundice obstructive. Methods Forty three patients who were diagnosed with malignant obstructive jaundice by contrast-enhanced computed tomography and contrast-enhanced computed magnetic resonance imaging were enrolled in this study. All of them underwent conventional ultrasound, IV-CEUS and IC-CEUS. According to the results of operation, the diagnosis accuracies were compared among conventional ultrasound, IV-CEUS, IC-CEUS and IV- CEUS combined with IC-CEUS. Results Diagnostic accuracy by the conventional ultrasound , IV-CEUS , IC-CEUS and IV- CEUS combined with IC-CEUS were 72.1%(31/43), 83.7%(36/43), 81.4%(35/43) and 93.0%(40/43), respectively. IV- CEUS combined with IC-CEUS was superior to the conventional ultrasound (P = 0.021). There were no significant differences when the conventional ultrasound was compared with IV-CEUS or IC-CEUS alone (P = 0.194 and 0.307). Conclusions Preoperative evaluation by IV- CEUS combined with IC-CEUS can elaborate the intra-cavitary and extra-cavitary changes of malignant obstructive jaundice. The diagnostic accuracy rate could be effectively improved by IV-CEUS combined with IC-CEUS, which can bring favorable clinical benefit.

3.
Chinese Traditional Patent Medicine ; (12)1992.
Article in Chinese | WPRIM | ID: wpr-682563

ABSTRACT

AIM: To set up identification of Flos Lonicerae and determination of chlorogenic acid in Yingqiao jiedu Pills (Flos Lonicerae, Fructus Forsythiae, Radix Glycyrrhizae, Herba Menthae, etc.) by HPLC. METHODS: A YWG C 18 column was used with the mobile phase consisted of CH 3OH 10%Na 2HPO 4 (adjusting pH to 2.7 with HAc) as gradient elution. The flow rate was 1.0mL?min -1 , and the detection wavelength was at 326nm. RESULTS: Flos Lonicerae in Yinqiaojiedu Pills was identified by HPLC UV. The linear range of chlorogenic acid was 5.0~60?g?mL -1 ( r =0.9999). The average recovery was 98.71% with RSD of 1.55% ( n =5). CONCLUSION: The method is simple, accurate and rapid with good reproducibility. It can be used for the quality control of Flos Lonicerae in Yinqiaojiedu Pills.

4.
Chinese Traditional Patent Medicine ; (12)1992.
Article in Chinese | WPRIM | ID: wpr-573338

ABSTRACT

AIM:To set up a determination of tanshinone Ⅱ_A and cryptotanshinone in Compound Danshen Tablet(Radix Salviae Miltiorrhizae, Radix Notoginseng, Borneolum Syntheticum) by RP-HPLC. METHODS:Two components could be separated through YWG-C_~18 column with methanol-water (75∶25 by volume) as a mobile phase. The flow rate was 1.0 mL?min~-1 , and the detection wavelength was at 270 nm. RESULTS: The linear range of tanshinone Ⅱ_A and cryptotanshinone were 2.5-50.0 ?g?mL~-1 and 0.625-12.5 ?g?mL~-1 , respectively. The average recovery was 99.76% with RSD 0.92% for tanshinone Ⅱ_A and 98.34% with RSD 0.71% for cryptotanshinone, respectively. CONCLUSION: The method is simple, accurate and rapid with good reproducibility. It can be used for the quality control of Compound Danshen Tablet.

SELECTION OF CITATIONS
SEARCH DETAIL